Modelled thermal performance and sustained processor power of the fanless Thinvent IPC5 and IPC3 industrial PCs
Will the fanless IPC5 or IPC3 run at your site?
- All-day running with no fan: In our thermal model (unit lying flat in still air), both the IPC5 and IPC3 sustain the base power of every processor they ship with (28 W on the Intel Core i5-1240P in the IPC5, and 15 W on the U-series processors in both models) all day without slowing down in room temperatures up to 50 °C, with a wide margin (sustaining a modelled 44 W on the IPC5 and 49 W on the IPC3 in a 50 °C room, rising to 66 W and 74 W in a 25 °C room).
- How warm the case gets: At continuous base power in a modelled 25, 35 and 45 °C room, the hottest point on the lid reaches 52, 61 and 70 °C on the IPC5 with the 28 W Core i5-1240P (average case surface 47, 57 and 66 °C); 42, 51 and 61 °C on the IPC5 with a 15 W processor; and 44, 53 and 62 °C on the IPC3 with a 15 W processor. The modelled processor temperature at those base loads is 61, 70 and 79 °C (IPC5 at 28 W), 47, 56 and 66 °C (IPC5 at 15 W) and 46, 55 and 65 °C (IPC3 at 15 W), well below its 100 °C limit.
- Short turbo bursts and heavy loads: Processors boost up to 64 W (i5-1240P) or 55 to 57 W (15 W class) for short bursts; in a modelled 35 °C room, a maximum turbo burst from idle takes the processor to about 63 °C (IPC5 at 28 W), 58 °C (IPC5 at 15 W) and 50 °C (IPC3 at 15 W) before it settles near 70, 56 and 55 °C at base power. Both units also sustain maximum turbo continuously up to about a modelled 27 °C room at 64 W on the IPC5, and up to about 37 °C on the IPC5 or 44 °C on the IPC3 at 55 W; in warmer rooms, a continuous turbo load reaches 100 °C and the processor lowers its own power (throttling) to stay there.
- Which model to choose: Choose the IPC5 (210 x 197 x 65 mm, black anodised finned aluminium) if you need the 28 W Intel Core i5-1240P, or a 15 W Core i5, i7, Core 5 or Core Ultra 5 processor. Choose the IPC3 (231 x 200 x 52 mm, silver anodised finned aluminium) if a 15 W Core i3 processor meets your needs and you want a slimmer case with side mounting flanges.
- Where you install it: All figures are modelled with the unit lying flat in open, still air, where room temperature is the air immediately around the PC. Putting a unit inside a closed cabinet warms that trapped air, so leave clear space around the fins and ventilate the cabinet so the air around the case stays within your target temperature.
Sustained processor power across room temperatures
Hottest case point by processor power and room temperature (28 W class)
Hottest case point by processor power and room temperature (15 W class)
Hottest and average case temperature against processor power
Processor junction temperature against processor power
Ninety-minute response from idle to a maximum turbo burst and base load
Whole lid surface temperature to scale at base power
Close-up of the warmest part of each lid at base power
Cross-section of the Thinvent IPC5 at 28 W base power
Cross-section of the Thinvent IPC3 at 15 W base power